{1277}
hide / / print
ref: -0 tags: polyimide anodic release 2005 date: 06-16-2014 23:58 gmt revision:1 [0] [head]

IEEE-1416914 (pdf) Partial release and detachment of microfabricated metal and polymer structures by anodic metal dissolution

  • recommend 100nm Cr/Al release layer.
  • finished devices just 'float to the surface' of saline solution.

{1178}
hide / / print
ref: -0 tags: parylene flexible neural recording drug delivery microfluidics 2012 inserter needle release date: 01-02-2013 22:41 gmt revision:1 [0] [head]

PMID-23160191 Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration

  • They seem to think that drugs are critical for success: "These features will enhance tissue integration and improve recording quality towards realizing reliable chronic neural interfaces."
  • Similar to Kennedy: "The sheath structure allows for ingrowth of neural processes leading to improved tissue/probe integration post implantation." 8 electrodes, 4 on the cone interior, 4 on the exterior.
    • opening is 50um at tip, 300 um at base.
  • Used a PEEK-stiffened parylene ZIF connection.
  • Only tested in agarose, but it did properly release from the inserter needle.
  • I wonder if we could use a similar technique..