Polyimide insulators for multilevel interconnections Arthur M. Wilson
- Old article (1981), but has useful historical information on the development of various PI insulators and their adhesion to aluminum, SiOx, etc.
- Suggests that a higher-temperature cure (400C) is needed to fully drive water from the PI & cause a glass-transition. Might want to do this for the second PI layer.
|