ref: -0 tags: bone marrow transplant chimera immune response to indwelling electrode implant capadona inflammation date: 02-02-2017 23:24 gmt revision:1 [0] [head]

PMID-24973296 The roles of blood-derived macrophages and resident microglia in the neuroinflammatory response to implanted intracortical microelectrodes.

  • Quite good introductory review on current understanding of immune / inflammatory / BBB breakdown response to indwelling neural implants.
  • Used chimera mice with marrow from CFP mice transplanted into irradiated hosts, so myeloid cells were labeled (including macrophages and monocytes).
    • Details of this process are properly fascinating ... there are clever ways of isolating and selecting the right marrow cells.
  • Implanted with a dummy Michigan style probe, 2mm x 123 um x 15um.
  • Histological processes and cell sorting / labeling also highly detailed.
  • 60% of the infiltrating cells (CFP+) are macrophages.
    • Within the total IBA1+ population (macrophages + microglia), we saw that only 20% of the total IBA1+ population was comprised of microglia at two weeks post implantation (Fig. 9G).
    • Additionally, at chronic time points (four, eight and sixteen weeks), we observed that less than 40% of the total IBA1+ population was comprised of microglia (Fig. 9G).
    • On the other hand, no significant differences were observed in microglia populations over time (Fig. 9G, Table 4). Together, our results suggest a predominant role of infiltrating macrophages surrounding implanted microelectrodes over time.
  • IBA1 = marker for ionized calcium binding adapter molecule, to label the total population of microglia/ macrophages (both resting and activated)
  • CD68 = activated microglia / macrophage.
    • Hard to discriminate microglia and infiltrating macrophages.
  • Interestingly, fluctuations in GFAP+ immunoreactivity correlated well with neuronal density and CFP+ immunoreactivty, suggesting a possible role of astrocytes in facilitating trafficking of blood-derived cells.
  • Contrary to what has been suggested by many intracortical microelectrode studies, a consistent connection was not found between activated microglia/macrophages and neuron density in our chimera models

{1204}
hide / edit[6] / print
ref: Linsmeier-2011.01 tags: histology lund electrodes immune response fine flexible review Thelin date: 12-08-2015 23:57 gmt revision:6 [5] [4] [3] [2] [1] [0] [head]

PMID-21867803[0] Can histology solve the riddle of the nonfunctioning electrode? Factors influencing the biocompatibility of brain machine interfaces.

  • We show results from an ultrathin multichannel wire electrode that has been implanted in the rat cerebral cortex for 1 year.
    • 12um Pt-Ir wires in a 200um bundle coated with gelatin. See PMID-20551508[1]
    • Electrode was left in the rat cortex for 354 days
    • no clear GFAP staining or ED1 positive cells at the electrode tips.
  • To improve biocompatibility of implanted electrodes, we would like to suggest that free-floating, very small, flexible, and, in time, wireless electrodes would elicit a diminished cell encapsulation.
  • Suggest standardized methods for the electrode design, the electrode implantation method, and the analyses of cell reactions after implantation
  • somewhat of a review -- Stice, Biran 2005 [2] 2007 [3].
  • 50um is the recording distance Purcell 2009.
  • See also [4]
  • Study of neuronal density and ED1 reactivity / GFAP:
    • Even at 12 weeks the correlation between NeuN density and GFAP / ED1 was small -- r 2=0.12
    • Note that DAPI labels many unknown cells in the vicinity of the electrode.

____References____

[0] Linsmeier CE, Thelin J, Danielsen N, Can histology solve the riddle of the nonfunctioning electrode? Factors influencing the biocompatibility of brain machine interfaces.Prog Brain Res 194no Issue 181-9 (2011)
[1] Lind G, Linsmeier CE, Thelin J, Schouenborg J, Gelatine-embedded electrodes--a novel biocompatible vehicle allowing implantation of highly flexible microelectrodes.J Neural Eng 7:4, 046005 (2010 Aug)
[2] Biran R, Martin DC, Tresco PA, Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.Exp Neurol 195:1, 115-26 (2005 Sep)
[3] Biran R, Martin DC, Tresco PA, The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.J Biomed Mater Res A 82:1, 169-78 (2007 Jul)
[4] Thelin J, Jörntell H, Psouni E, Garwicz M, Schouenborg J, Danielsen N, Linsmeier CE, Implant size and fixation mode strongly influence tissue reactions in the CNS.PLoS One 6:1, e16267 (2011 Jan 26)

{1238}
hide / edit[4] / print
ref: -0 tags: histology immune response otto indiana electrodes gfap inflamation transparent clearing vimentin date: 04-19-2013 23:59 gmt revision:4 [3] [2] [1] [0] [head]

PMID-23428842 Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses.

  • Woolley AJ, Desai HA, Otto KJ.
  • One timepoint, 4 weeks.
  • Laser confocal microscopy
    • after tissue clearing (optical index of refraction matching) in a 60% sucrose solution.
  • Single-shank iridium contact silicon substrate MEA.
    • Device cut level with surface of brain after insertion.
  • Intact MEAs via device-capture histology, DHhist (Woolley et al 2011)
    • 350-450um tissue explanted with device.
    • They promote their technique.
  • Tissue surrounding microdevices exhibited two major depth-related phenomena:
    • a non-uniform microglial coating along the device length and
    • a dense mass of cells surrounding the implant in cerebral cortical layers I and II.
      • The dense mass of cells contained vimentin, a protein not typically expressed highly in CNS cells, evidence that non-CNS cells likely descended down the face of the penetrating devices from the pial surface.
        • But no Iba1 (activated microglia) per se in the tissue mass.
    • Hoe342 -- cell marker.
    • This mass was apparently consistent across animals!
    • Cells in the mass were VIM positive -- fibroblasts -- meninges?
  • low GFAP = not an astrocytic scar.
  • This study provides further evidence that a progressive invasion of non-CNS cells contributes substantially to the chronic phase of the tissue response around intracortical MEAs.
    • Again, might be from BBB distruption {1237}


This result is supported by previous papers:
  • {1193} -- microglia response not correlated to electrode failure, but correlated to ferritin immunoresponse
  • {781} -- also note that menigeal fibroblasts migrate down electrode tracts.
  • {1028} -- measured vimentin, GFAP, and ED1 (not Iba1). Found Vim+ and GFAP+, suggesting reactive astrocytes and not meningeal cells. ED1 aka CD68 is specific to macrophages and not microglia, so these may be blood-derived cells.
  • {1200} -- chronic contact with the meninges v.s intraparenchymal correlated with Vim+ encapsulation.
  • {1210} -- old paper showing the same result near surface of implant.
  • {1196} -- more against GFAP & pro BBB disruption
  • {1204} -- GFAP uncorrelated (!) with NeuN intensity
  • {307} -- all initial tests of utah arrays showed fibrous encapsulation; one array was completely explanted. This is why now they put gore-tex over the implant -- to prevent fibroblast migration (i guess).

{1237}
hide / edit[0] / print
ref: -0 tags: winslow Tresco 2010 BBB histology immune response microelectrodes date: 04-19-2013 23:25 gmt revision:0 [head]

PMID-19963267 Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex.

  • Winslow BD, Tresco PA.
  • The spatial distribution of biomarkers associated with the foreign body response to insulated microwires placed in rat cerebral cortex was analyzed 2, 4, and 12 weeks after implantation using quantitative methods.
  • We found no evidence that reactive gliosis increases over time or that neuronal loss is progressive, we did find evidence of persistent inflammation and enhanced BBB permeability at the electrode brain tissue interface that extended over the 3 month indwelling period and that exhibited more animal to animal variability at 3 months than at 2 and 4 weeks.

{1223}
hide / edit[1] / print
ref: Neary-2003.03 tags: histology astrocyte response date: 01-29-2013 01:02 gmt revision:1 [0] [head]

PMID-12657694[0] High rate shear strain of three-dimensional neural cell cultures: a new in vitro traumatic brain injury model.

  • Astrocytes have mechanoreceptors that induces ERK signaling.
    • ERK =extracellular signal-regulated protein kinase, a key regulator of cellular proliferation and differentiation.

____References____

[0] Neary JT, Kang Y, Willoughby KA, Ellis EF, Activation of extracellular signal-regulated kinase by stretch-induced injury in astrocytes involves extracellular ATP and P2 purinergic receptors.J Neurosci 23:6, 2348-56 (2003 Mar 15)

{781}
hide / edit[10] / print
ref: Polikov-2005.1 tags: neural response glia histology immune electrodes recording 2005 Tresco Michigan microglia date: 01-29-2013 00:34 gmt revision:10 [9] [8] [7] [6] [5] [4] [head]

PMID-16198003[0] Response of brain tissue to chronically implanted neural electrodes

  • Good review (the kind where figures are taken from other papers). Nothing terribly new (upon a very cursory inspection)
  • When CNS damage severs blood vessels, microglia are indistinguishable from the blood borne, monocyte-derived macrophages that are recruited by the degranulation of platelets and the cellular release of cytokines.
  • Furthermore, microglia are known to secrete, either constitutively, or in response to pathological stimuli, neurotrophic factors that aid in neuronal survival and growth.
    • Also release cytotoxic and neurotoxic factors that can lead to neuronal death in vitro.
    • It has been suggested that the presence of insoluble materials in the brain may lead to a state of 'frustrated phagocytosis' or inability of the macrophages to remove the foreign body, resulting in persistent release of neurotoxic substances.
  • When a 10x10 array of silicon probes was implanted in feline cortex, 60% of the needle tracks showed evidence of hemorrhage and 25% showed edema upon explantation of the probes after one day (Schmidt et al 1993) {1163}
    • Although a large number of the tracks were affected, only 3-5% of the area was actually covered by hemorrhages and edema, suggesting the actual damage to blood vessels may have been relatively minor. (!!)
  • Excess fluid and cellular debris diminishes 6-8 days due to the action of activated microglia and re-absorption.
  • As testament to the transitory nature of this mechanically induced wound healing response, electrode tracks could not be found in animals after several months when the electrode was inerted and quickly removed (Yuen and Agnew 1995, Rousche et al 2001; Csicsvari et al 2003, Biran et al 2005).
  • Biran et al 2005: observed persistent ED-1 immunoreactivity around silicon microelectrode arrays implanted in rat cortex at 2 and 4 weeks following implantation; not seen in microelectrode stab wound controls.
  • On the glial scar:
    • observed in the CNS of all vertebrates, presumably to isolate damaged parts of the nervous system and maintain the integrity of the blood-brain barrier.
    • mostly composed of reactive astrocytes.
    • presumably the glial scar insulates electrodes from nearby neurons, hindering diffusion and increasing impedance.
  • On the meninges:
    • Meningeal fibroblasts, which also stain for vimentin, but not for GFAP, may migrate down the electrode shaft from the brain surface and form the early basis for the glial scar.
  • On recording quality:
    • Histological examination upon explantation revealed that every electrode with stable unit recordings had at least one large neuron near the electrode tip, while every electrode that was not able to record resolvable action potentials was explanted from a site with no large neurons nearby.
  • Perhaps the clearest example of this variability was observed in the in vivo response to plastic “mock electrodes” implanted in rabbit brain by Stensaas and Stensaas (1976) {1210} and explanted over the course of 2 years. They separated the response into three types: Type 1 was characterized by little to no gliosis with neurons adjacent to the implant, Type 2 had a reactive astrocyte zone, and Type 3 exhibited a layer of connective tissue between the reactive astrocyte layer and the implant, with neurons pushed more than 100 um away. All three responses are well documented in the literature; however this study found that the model electrodes produced all three types of reactions simultaneously,depending on where along the electrode one looked.

____References____

[0] Polikov VS, Tresco PA, Reichert WM, Response of brain tissue to chronically implanted neural electrodes.J Neurosci Methods 148:1, 1-18 (2005 Oct 15)

{748}
hide / edit[4] / print
ref: Leung-2008.08 tags: biocompatibility alginate tissue response immunochemistry microglia insulation spin coating Tresco recording histology MEA date: 01-28-2013 21:19 gmt revision:4 [3] [2] [1] [0] [head]

PMID-18485471[0] Characterization of microglial attachment and cytokine release on biomaterials of differing surface chemistry

  • The important result is that materials with low protein-binding (e.g. alginate) have fewer bound microglia, hence better biocompatibility. It also seems to help if the material is highly hydrophilic.
    • Yes alginate is made from algae.
  • Used Michigan probes for implantation.
  • ED1 = pan-macrophage marker.
    • (quote:) Quantification of cells on the surface indicated that the number of adherent microglia appeared higher on the smooth side of the electrode compared to the grooved, recording site side (Fig. 2B), and declined with time. However, at no point were electrodes completely free of attached and activated microglial cells nor did these cells disappear from the interfacial zone along the electrode tract.
    • but these were not coated with anything new .. ???

____References____

[0] Leung BK, Biran R, Underwood CJ, Tresco PA, Characterization of microglial attachment and cytokine release on biomaterials of differing surface chemistry.Biomaterials 29:23, 3289-97 (2008 Aug)

{1220}
hide / edit[0] / print
ref: -0 tags: histology review electrode response bioactive coatings date: 01-28-2013 20:16 gmt revision:0 [head]

PMID-20577634 Biocompatibility of intracortical microelectrodes: current status and future prospects.

  • ... but the most widely used method to enhance biocompatibility is the chemical modification of neural probe surfaces with anti-inflammatory compounds, adhesion proteins, or bioactive molecules (Heiduschka and Thanos, 1998; He et al., 2006; Ludwig et al., 2006; Moxon et al., 2007; Rennaker et al., 2007; Seymour and Kipke, 2007; Zhong and Bellamkonda, 2007; Leung et al., 2008; Williams, 2008; Grill et al., 2009)
    • Have any of these achieved success?
    • Many other polymers are basically biocompatible, provided they still insulate after equilibriating with the surrounding vapor pressure.
    • Personally I don't think biocoatings wil lmatter much if there is persistent shear at the interface.
  • Does make sense to have the electrode surface attractive to neurons (Kennedy..). For a later date.

{1200}
hide / edit[7] / print
ref: Kim-2004.05 tags: histology electrode immune response Tresco hollow fiber membranes GFAP vimentin ED1 date: 01-28-2013 03:08 gmt revision:7 [6] [5] [4] [3] [2] [1] [head]

PMID-14741588[0] Chronic response of adult rat brain tissue to implants anchored to the skull.

  • The increase in tissue reactivity observed with transcranially implanted HFMs may be influenced by several mechanisms including chronic contact with the meninges and possibly motion of the device within brain tissue.
  • Broadly speaking, our results suggest that any biomaterial, biosensor or device that is anchored to the skull and in chronic contact with meningeal tissue will have a higher level of tissue reactivity than the same material completely implanted within brain tissue.
  • See also [1]
  • Could slice through the hollow fiber membrane for histology. (as we shall).
  • Good list of references.

____References____

[0] Kim YT, Hitchcock RW, Bridge MJ, Tresco PA, Chronic response of adult rat brain tissue to implants anchored to the skull.Biomaterials 25:12, 2229-37 (2004 May)
[1] Biran R, Martin DC, Tresco PA, The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.J Biomed Mater Res A 82:1, 169-78 (2007 Jul)

{898}
hide / edit[8] / print
ref: Ward-2009.07 tags: microelectrode arrays immune response recording MEA Purdue date: 01-28-2013 01:52 gmt revision:8 [7] [6] [5] [4] [3] [2] [head]

PMID-19486899[0] Toward a comparison of microelectrodes for acute and chronic recordings.

  • Good research, paper well written.
  • Results suggest significant variability within and between microelectrode types with no clearly superior array (from the abstract).
  • As Miguel mantains, "Much of the new technology, however, does not supersede traditional microwire technology in its ability to evade a host immune response".
  • Initial implantation wound initiates a cascade of immune responses which culminates in a sheath of microglia, astrocytes, various ectracellular matrix constituents, and macrophages.
    • Decent citation list -- many people have been working on MEAs.
  • Fibrous encapusulation of the electrode is much less conductive than healthy nervous tissue, hence impedance measurements can be used to track tissue response.
  • Used Osort to sort the recorded neurons.
  • "Despite differing implant locations, and thus potentially differing levels of background neural activity, and differing scarring responses, which relates to the level of thermal noise in the observed signal (Ludwig et al., 2006), no significant SNR differences were observed among the MEA types for the duration of the study."
  • SNR trends did not seem to relate to site impedance trends over the 31-day period, and by inference, the extent of tissue encapsulation and neuronal density loss.
    • SNR is likely controlled by background neural noise, not thermal noise (which would be linked to impedance).
  • Electrodes with lower impedance generally recorded units from more sites than arrays with higher impedance.

____References____

[0] Ward MP, Rajdev P, Ellison C, Irazoqui PP, Toward a comparison of microelectrodes for acute and chronic recordings.Brain Res 1282no Issue 183-200 (2009 Jul 28)

{736}
hide / edit[7] / print
ref: Liu-1999.09 tags: electrodes recording tissue response MEA histology date: 01-28-2013 00:24 gmt revision:7 [6] [5] [4] [3] [2] [1] [head]

PMID-10498377[0] Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes.

  • implanted 7-shaft 35um iridium electrodes into the pericruciate gyrus of cats & measured the stability of recordings over several months.
  • electrodes were floating, under the dura; they note that connective tissue can force these floating arrays out of the brain, in further, or can encapsulate the electrodes.
    • electrodes activated by 'potentiodynamic cycling' to remove the insulation from the tip, I guess.
    • Insulation is epoxylite epoxy (5-10um thick) which is baked for curing and degassing at 100 and 170C each for 30 minutes.
    • more information on their fabrication in {1105}
  • Used the now-standard techniques for recording & analysis - amazing that this was all very new 10 years ago!
  • Measure stability not only on waveform shape (which will change as the position of the electrode relative to the neuron changes) but also neural tuning.
  • Lymphocytes were found to accumulate around the tips of the microstimulated sites.
  • Electrode sites that yielded recordings ('active') were all clean, with large neurons near the end, and with minimal connective tissue sheath (2-8 um; distance to nearby neurons was 30-50um).
    • Longest period for an active electrode was 242 days.
    • Electrode impedance was usually between 50 and 75 kOhm; there was no insulation failure.
  • Electrodes were stable even when the cat vigorously shook it's head in response to water placed on the head (!).
  • Electrodes were very unstable the first 2 weeks - 1 month ; rather stable thereafter.
    • Active electrodes tended to remain active ; inactive electrodes tended to remain inactive.

____References____

[0] Liu X, McCreery DB, Carter RR, Bullara LA, Yuen TG, Agnew WF, Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes.IEEE Trans Rehabil Eng 7:3, 315-26 (1999 Sep)
[1] Bullara LA, McCreery DB, Yuen TG, Agnew WF, A microelectrode for delivery of defined charge densities.J Neurosci Methods 9:1, 15-21 (1983 Sep)

{897}
hide / edit[5] / print
ref: Harris-2011.08 tags: microelectrodes nanocomposite immune response glia recording MEA date: 01-27-2013 22:19 gmt revision:5 [4] [3] [2] [1] [0] [head]

PMID-21654037[0] In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes

  • J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler and J R Capadona Case Western University.
  • Simple idea: electrodes should be rigid enough to penetrate the brain, yet soft enough to not damage it once implanted.
  • Many studies have shown that shear stress around a microelectrode shaft causes neural die-off and glial response.
  • You can only record from neurons if they are < 100um from the electrode tip.
  • Nanocomposite material is inspired by sea cucumber skin.
    • Our materials exhibit this behaviour by mimicking the architecture and proposed switching mechanism at play in the sea cucumber dermis by utilizing a polymer NC consisting of a controllable structural scaffold of rigid cellulose nanofibres embedded within a soft polymeric matrix. When the nanofibres percolate, they interact with each other through hydrogen bonding and form a nanofibre network that becomes the load-bearing element, leading to a high overall stiffness of the NC. When combined with a polymer system which additionally undergoes a phase transition at physiologically relevant temperatures, a contrast of over two orders of magnitude for the tensile elastic modulus is exhibited.
  • Probes were 200um wide, 100um thick, and had a point sharpened to 45deg.
  • Buckle force testing was done on 53um thick, 125um wide probes sharpened to a 30deg point.
  • Penetration stress through the rat pia is 1.2e7 dynes/cm^2 for a Si probe 40um thick and 80um wide.
  • See also {1198}

____References____

[0] Harris JP, Hess AE, Rowan SJ, Weder C, Zorman CA, Tyler DJ, Capadona JR, In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.J Neural Eng 8:4, 046010 (2011 Aug)

{1210}
hide / edit[1] / print
ref: Stensaas-1976.01 tags: histology implant electrodes immune response date: 01-25-2013 02:52 gmt revision:1 [0] [head]

PMID-782142[0] The reaction of the cerebral cortex to chronically implanted plastic needles.

  • Three different classes of result:
    • Type I is characterized by little or no gliosis and synapses within 1-5mu of the implant;
    • type II contains a pronounced zone of reactive astrocytes;
    • type III is typified by a zone of connective tissue near the implant surface
      • One implant can evince all 3 different types!
  • Already were thinking of neuroprosthetic devices.

____References____

[0] Stensaas SS, Stensaas LJ, The reaction of the cerebral cortex to chronically implanted plastic needles.Acta Neuropathol 35:3, 187-203 (1976)

{1196}
hide / edit[5] / print
ref: Skousen-2011.01 tags: electrodes immune response Tresco Wise Michigan histology GFAP atrocyte surface area foreign body response date: 01-25-2013 01:44 gmt revision:5 [4] [3] [2] [1] [0] [head]

PMID-21867802[0] Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays.

  • We studied the chronic brain foreign body response to planar solid silicon microelectrode arrays and planar lattice arrays with identical penetrating profiles but with reduced surface area in rats after an 8-week indwelling period.
  • Using quantitative immunohistochemistry, we found that presenting less surface area after equivalent iatrogenic injury is accompanied by significantly less
    • persistent macrophage activation,
    • decreased blood brain barrier leakiness,
    • and reduced neuronal cell loss.
  • Could be a factor of micromotion, too -- the lattice array has more anchoring points (?)
  • They propose it's a factor of TNF- α concentration around the implants. This, and other proinflammatory and cytoxic cytokines, is released by macrophages.
  • "Recent studies from our lab have described disruption of BBB integrity, indicated by the presence of autologous IgG in the brain parenchyma, surrounding both microwire and planar silicon recording devices ([1][2]. Under normal conditions, autologous IgG is excluded from the brain parenchyma (Azzi et al., 1990; Seitz et al., 1985) but has been observed following BBB disruption (Aihara et al., 1994).
    • E.g. the presence of IgG proves that the BBB was compromised.
      • Less so with the lattice implants.
  • Previous work from our lab using single microwires and single shaft, planar silicon microelectrode arrays indicated that the spatial distribution of GFAP does not increase with time over the indwelling period and did not support the “increase in astrogliosis over time hypothesis” as a dominant or general biologically related failure mechanism for this type of microelectrode recording device {1197}.

____References____

[0] Skousen JL, Merriam SM, Srivannavit O, Perlin G, Wise KD, Tresco PA, Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays.Prog Brain Res 194no Issue 167-80 (2011)
[1] Winslow BD, Christensen MB, Yang WK, Solzbacher F, Tresco PA, A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex.Biomaterials 31:35, 9163-72 (2010 Dec)
[2] Winslow BD, Tresco PA, Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex.Biomaterials 31:7, 1558-67 (2010 Mar)

{1026}
hide / edit[5] / print
ref: Thelin-2011.01 tags: histology MEA tether tissue response malmo lund date: 01-24-2013 22:17 gmt revision:5 [4] [3] [2] [1] [0] [head]

PMID-21298109[0] Implant size and fixation mode strongly influence tissue reactions in the CNS.

  • Overview: tethering and size both increase immune response, and causes continued GFAP activity.
    • An untethered 50um electrode exhibited very weak inflammatory response after 12 weeks.
      • Suggesting that a small electrode can move with the brain.
  • Tethering in their context means affixed rigidly to the bone.
    • Small-diameter, untethered implants cause the smallest tissue reactions.
    • Likely that this scales.
  • Stice et al 2007 {1111} -- GFAP expression was significantly smaller for 12 um diameter implants than 25um implants @ 4 weeks.
  • They used 50um and 200um stainless steel implants.
    • implants glued to micromanipulator using gelatine
  • 24 rats.
  • Much more GFAP and ED1 actviity in tethered implants; NEuN neural density about the same.
  • 50um implant had a higher NeuN + count.
  • Regarding implantation: not sure. Have to find a reference for stab wounds (where the inserter is retracted).

____References____

[0] Thelin J, Jörntell H, Psouni E, Garwicz M, Schouenborg J, Danielsen N, Linsmeier CE, Implant size and fixation mode strongly influence tissue reactions in the CNS.PLoS One 6:1, e16267 (2011 Jan 26)

{737}
hide / edit[5] / print
ref: Biran-2005.09 tags: microelectrode Michigan probe glia tissue response electrode immune histology MEA Biran date: 01-24-2013 20:49 gmt revision:5 [4] [3] [2] [1] [0] [head]

PMID-16045910[0] Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.

  • See also {1190} (wow, I'm redundant!)
  • Important point: ED1 up-regulation and neuronal loss were not observed in microelectrode stab controls, indicating that the phenotype did not result from the initial mechanical trauma of electrode implantation, but was associated with the foreign body response.
    • CD68 = ED1 is a marker for microglia and other macrophages. (wikipedia article is informative).
    • GFAP = glial fibrillary acidic protein, marker for astrocytes.
  • Recording failure is caused by chronic inflammation (mostly activated microglia) at the microelectrode brain tissue interface.
  • Only tested response 2 and 4 weeks after implantation. Makes sense for stab wound, but didn't the want to see a longer term response? Or do their electrodes just not last that long?
  • What did they coat the silicon probes in?
  • Used silastic to shock-mount their floating electrodes, but this apparently made no difference compared to conventional dental cement and bone screw mounting.
  • Suggest that chronic inflammatory response may be related to the absorption of fibrogen and complement to the surface of the device (device should not be porous?), the subsequent release of pro-inflammatory and cytotoxic cytokines by activated microphages, and the persistence of activated macrophages around materials which cannot be broken down.
    • Well then, how do you make the electrodes biochemically / biologically 'invisible'?
    • Persistently activated microglia are found around insoluble plaques in AD (plaques that cannot be / are not removed from the brain via proteolysis. Microglia form 'glitter cells' when they engulf undigestible stubstances). This has been termed 'frustrated phagocytosis', which results in increased secretion of proinflamatory cytokines that directly or indirectly cause neuronal death.
  • Significant reductions in neurofiliament reactivity was seen up to 230um from the microelectrode interface; this was not seen for stab wounds. Maximum recording distance is about 130um; 100um more reasonable in normal conditions.
  • Accumulating evidence from postmortem analysis of patients implanted with DBS electrodes reveals that chronic neuroinflamation is part of the response to such (duller, larger) implants as well. They have seen cell loss up to 1mm fromt the electrode surface here.

____References____

[0] Biran R, Martin DC, Tresco PA, Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.Exp Neurol 195:1, 115-26 (2005 Sep)

{1199}
hide / edit[1] / print
ref: -0 tags: histology atryocytes immune response electrode arrays lund multiple exacerbate date: 01-24-2013 19:56 gmt revision:1 [0] [head]

PMID-23091629 Multiple implants do not aggravate the tissue reaction in rat brain.

  • After six weeks, the astrocytic scar surrounding the middle out of five implants was significantly smaller compared to the single contralateral implant, suggesting that an intrahemispheric interaction might be taking place, reducing the astrocytic response around the central implant.
  • Weak (?) staining for ED1 in this study?
  • -- after 6 weeks.
  • Thought: every paper has a different method for quantify immune response, GFAP staining in this case.

{1142}
hide / edit[1] / print
ref: -0 tags: globus pallidus delong response tuning date: 02-24-2012 21:41 gmt revision:1 [0] [head]

PMID-4997823 Activity of Pallidal Neurons During Movement

  • GPe activity notably different from GPi.
    • "So characteristic were the discharge patterns of units in each segment that early in the course of the experiment ti be came apparent when the electrode entered and left each segment.
  • Two types of cells in GPe:
    • High frequency with periods of quiet (85%)
    • Low frequency with bursts.
  • Only one type in GPi: continuous HF discharge, 10-100 Hz, mean 63 Hz.
  • Mostly contralateral, ~ 15% ipsilateral related discharge.
  • Leg and arm responding units intermixed.
  • Conclusion: pallidus not involved in reflexes.
  • Substantia innominata = region posterior the pallidus, contains the nucleus basalis.
  • I'd really like to get recordings of this quality!

{264}
hide / edit[2] / print
ref: Maravita-2004.02 tags: tool use monkey mirror neurons response learning date: 09-24-2008 17:02 gmt revision:2 [1] [0] [head]

PMID-15588812[0] Tools for the body schema

See also PMID-8951846[1] Coding of modified body schema during tool use by macaque postcentral neurones.

____References____

{263}
hide / edit[1] / print
ref: Ferrari-2005.02 tags: tool use monkey neural response leaning mirror neurons F5 date: 04-03-2007 22:44 gmt revision:1 [0] [head]

PMID-15811234[] Mirror Neurons Responding to Observation of Actions Made with Tools in Monkey Ventral Premotor Cortex

  • respond when the monkey sees a human using a tool!

____References____

{36}
hide / edit[0] / print
ref: bookmark-0 tags: spiking neuron models learning SRM spike response model date: 0-0-2006 0:0 revision:0 [head]

http://diwww.epfl.ch/~gerstner/SPNM/SPNM.html

{44}
hide / edit[0] / print
ref: notes-0 tags: spike patterns neural response LGN spike_timing Sejnowski vision date: 0-0-2006 0:0 revision:0 [head]

http://www.jneurosci.org/cgi/reprint/24/12/2989.pdf

  • quote: " when a cortical neuron is repeatedly injected with the same fluctuating current stimulus, the timing of the spikes is highly precise from trial to trial and the spike pattern appears to be unique"
    • though: I'd imagine that somebody has characterized the actual transfer function of this.
  • mais: we conclude that the prestimulus history of a neuron may influence the precise timing of the spikes in repsonse to a stimulus over a wide range of time scales.
  • in vivo, it is hard to find patterns because neurons may jump between paterns & there is a large ammount of neuronal noise in there too. or there may be neural "attractors".
  • they observed long-term (seconds) firing patterns in cat LGN (interesting)