m8ta
you are not logged in, login. new entry
text: sort by
tags: modified
type: chronology
{1374}
hide / edit[3] / print
ref: -0 tags: nanoprobe transmembrane intracellular thiol gold AFM juxtacellular date: 02-06-2017 23:45 gmt revision:3 [2] [1] [0] [head]

PMID-20212151 Fusion of biomimetic stealth probes into lipid bilayer cores

  • Used e-beam evaporation of Cr/Au/Cr 10/10/10 or 10/5/10 onto a Si AFM tip.
    • Approx 200nm diameter; 1800 lipid interaction at the circumference.
  • Exposed the Au in the sandwich via FIB
  • Functionalized the Au with butanethiol or dodecanthiol; former is mobile on the surface, latter is polycrystaline.
    • Butanethiol showed higher adhesion to the synthetic membranes
  • Measured the penetration force & displacement through synthetic multi-layer lipid bilayers.
    • These were made via a custom protocol with 1-stearoyl-2-oleoyl-sn-glycero-3-phosphocholine (SOPC) and cholesterol

PMID-21469728 '''Molecular Structure Influences the Stability of Membrane Penetrating Biointerfaces.

  • Surprisingly, hydrophobicity is found to be a secondary factor with monolayer crystallinity the major determinate of interface strength
  • Previous studies using ellipsometry and IR spectroscopy have shown that alkanethiol self-assembled monolayers display an abrupt transition from a fluid to a crystalline phase between hexanethiol and octanethiol.
    • This suggests the weakening of the membrane stealth probe interface is due to the crystallinity of the molecular surface with fluid, disordered monolayers promoting a high strength interface regime and rigid, crystalline SAMs forming weak interfaces.

{841}
hide / edit[4] / print
ref: Tian-2010.08 tags: nanowire nanoprobe silicon FET doping cis trans extracellular intracellular recording neuro MEA date: 01-03-2012 16:35 gmt revision:4 [3] [2] [1] [0] [head]

PMID-20705858[0] Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes

  • Made a silicon nanowire with 60 deg. kinks via trans/cis manipulation.
  • Doped one part of the N nanowire P to make a 200nm long FET whose gate is simply the surface of the nanowire (I think, have to check the refs)
  • Attached the nanoprobe / nanowire to flexible PMMA / SM-8 support which, due to interfacial stress, rose off the substrate (clever!)
  • Coated tip with phospholipid layers -> better cell attachment / penetration.
    • Possible to have the cell pull the nanoprobe in via endocytic pathways.
  • Were able to record intracellular and extracellular AP from rabbit cardiocytes. (!!!)

____References____

[0] Tian B, Cohen-Karni T, Qing Q, Duan X, Xie P, Lieber CM, Three-dimensional, flexible nanoscale field-effect transistors as localized bioprobes.Science 329:5993, 830-4 (2010 Aug 13)