m8ta
you are not logged in, login. new entry
text: sort by
tags: modified
type: chronology
[1] Obeid I, Nicolelis MA, Wolf PD, A low power multichannel analog front end for portable neural signal recordings.J Neurosci Methods 133:1-2, 27-32 (2004 Feb 15)

{1392}
hide / edit[0] / print
ref: -0 tags: lieber mesh electronics SU-8 recording electrodes flexible polymer glass capillary date: 12-22-2017 00:14 gmt revision:0 [head]

PMID-29109247 Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology

  • Key change was the addition of multiple conductor traces per longitudinal mesh line; this allows them to get 64 or 128 channels per mesh without a dramatic increase in modulus.
  • The latitudinal / diagonal lines still displace tissue ...
  • And the injection mechanism, glass pipette, 650um OD, 400um ID, is pretty large, even for 128 channels.
  • Use carbon nanotube ink, custom CNC printer, to connect to FPC.
    • Pretty impressive that they can manipulate ~800nm thick Su-8 film intraop and have it work well!

{1352}
hide / edit[1] / print
ref: -0 tags: Charles Lieber syringe-injectable electronics SU-8 chronic flexible date: 10-14-2016 23:30 gmt revision:1 [0] [head]

PMID-27571550 Stable long-term chronic brain mapping at the single-neuron level.

  • Fu TM, Hong G1, Zhou T1, Schuhmann TG, Viveros RD2, Lieber CM.
  • 8 months with only 800nm of Su-8 (400nm of insulation!!). This is both surprising and very impressive; we have to step up our game!
  • In a mouse, too - their surgical technique must be very good. Mice only live ~ 2 years anyway.
  • Figure 3 -- stability -- incredible.
  • Recording sites were bare platinum, 20um diameter; stimulation sites were also bare Pt, 150um dia.
    • No plating or mircowire-fets, so far as I can see; electrode impedances were stable at 200 - 600k (supplementary figure 12).

{314}
hide / edit[4] / print
ref: Obeid-2004.02 tags: Wolf BMI recording electronics telemetry Obeid date: 12-31-2011 18:27 gmt revision:4 [3] [2] [1] [0] [head]

PMID-14757341[1] A low power multichannel analog front end for portable neural signal recordings.

  • have an interesting section on CMRR, quote: Although we use a precision differential amplifier with a CMRR of 110 dB, we were unable, in practice, to measure CMRRs greater than not, vert, similar42 dB. This can be accounted for by the device tolerances in the preamplifier stage; using ±0.1% resistors and ±5% capacitors in the preamplifier, the expected worst case CMRR at 1 kHz is 39.2 dB

____References____

{444}
hide / edit[5] / print
ref: notes-0 tags: nordic pinout nRF24L01 spark fun electronics date: 10-09-2007 19:59 gmt revision:5 [4] [3] [2] [1] [0] [head]

nordic semi links:

here is the connection list for the nRF24L01 module made by sparkfunelectronics
  1. VCC
  2. CE
  3. CSN
  4. SCK
  5. MOSI
  6. MISO
  7. IRQ
  8. GND
(1 is by the voltage regulator, obviously.) reversed:
  1. GND
  2. IRQ
  3. MISO
  4. MOSI
  5. SCK
  6. CSN
  7. CE
  8. VCC