{1395}
hide / edit[0] / print
ref: -0 tags: Courtine e-dura PDMS silicone gold platinum composite stretch locomotion restoration rats date: 12-22-2017 01:59 gmt revision:0 [head]

PMID-25574019 Biomaterials. Electronic dura mater for long-term multimodal neural interfaces.

  • Fabrication:
    • 120um total PDMS thickness, made through soft lithography, covalent (O2 plasma) bonding between layers
    • 35nm of Au (thin!) deposited through a stencil mask.
    • 300um Pt-PDMS composite for electrode sites, deposited via screenprinting
  • 100 x 200um cross section drug delivery channel.
  • Compared vs. stiff 25um thick PI film electrode.
    • stiff implants showed motor impairments 1-2 weeks after implantation.
  • Showed remarkable recovery of supported locomotion with stimulation and drug infusion (to be followed by monkeys).

{1394}
hide / edit[0] / print
ref: -0 tags: Courtine PDMS soft biomaterials spinal cord e-dura date: 12-22-2017 01:29 gmt revision:0 [head]

Materials and technologies for soft implantable neuroprostheses

  • Quote: In humans, both the spinal cord and its meningeal protective membranes can experience as much as 10–20% tensile strain and
displacement (relative to the spinal canal) during normal postural movements. This motion corresponds to displacements on the order of centimetres17. The deformations relative to the spinal cord in animal models, such as rodents or non-human primates, are likely to be even larger.

{1229}
hide / edit[2] / print
ref: -0 tags: parylene PDMS material properties gold compliant date: 02-08-2013 22:38 gmt revision:2 [1] [0] [head]

PMID-21240559 Highly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS

  • he microcable electrodes were also electromechanically tested, with measurable conductivity (220 kΩ) at an average 8% strain (n = 2) after the application of 200% strain.

{1189}
hide / edit[0] / print
ref: -0 tags: microelectrode array flexible PDMS via interconnect Georgia date: 01-04-2013 00:33 gmt revision:0 [head]

IEEE-6197244 (pdf) A PDMS-Based Integrated Stretchable Microelectrode Array (isMEA) for Neural and Muscular Surface Interfacing

  • Targeted at e.g. ECoG; in this paper, they look at cat muscle (epimyscial recording).
  • MEA is directly fabricated with a stretchable substrate, such as a thin PCB or ASIC, through via bonding for built-in packaging.